From: Evaluating the safety and efficiency of robotic dispensing systems
Period 1 | Period 2 | Period 3 | ||||
---|---|---|---|---|---|---|
Number (%) | Number (%) | p-values vs Period 1 | Number (%) | p-values vs Period 1 | p-values vs Period 2 | |
Prescribed medications | 158,548 (100%) | 106,611 (100%) | 114,111 (100%) | |||
Prevented dispensing errors | ||||||
Wrong quantity | 170 (0.107%) | 28 (0.026%) | < 0.001* | 32 (0.028%) | < 0.001* | 0.897 |
Wrong strength | 83 (0.052%) | 3 (0.003%) | < 0.001* | 0 (0%) | < 0.001* | 0.113 |
Wrong drug | 39 (0.025%) | 5 (0.005%) | < 0.001* | 1 (0.001%) | < 0.001* | 0.113 |
Wrong dosage form | 16 (0.010%) | 0 (0%) | < 0.001* | 0 (0%) | < 0.001* | NA |
Others | 16 (0.010%) | 22 (0.021%) | 0.031 | 17 (0.015%) | 0.292 | 0.339 |
TOTAL | 324 (0.204%) | 58 (0.054%) | < 0.001* | 50 (0.044%) | < 0.001* | 0.290 |
Unprevented dispensing errors | ||||||
Wrong quantity | 12 (0.008%) | 3 (0.003%) | 0.123 | 0 (0%) | 0.002* | 0.113 |
Wrong strength | 1 (0.001%) | 0 (0%) | 1.000 | 0 (0%) | 1.000 | NA |
Wrong drug | 4 (0.003%) | 0 (0%) | 0.154 | 0 (0%) | 0.145 | NA |
Wrong dosage form | 2 (0.001%) | 0 (0%) | 0.519 | 0 (0%) | 0.513 | NA |
Others | 5 (0.003%) | 2 (0.002%) | 0.709 | 2 (0.002%) | 0.707 | 1.000 |
TOTAL | 24 (0.015%) | 5 (0.005%) | 0.013* | 2 (0.002%) | < 0.001* | 0.274 |