Skip to main content

Table 1 Accuracy and precision study on the (±)-tramadol assay

From: Photostability studies on (±)-tramadol in a liquid formulation

Nominal

 

Run-to-run assay

Day-to-day assay

concentration (ng/μL)

 

Detected (ng/μL)

Accuracy (%)

CV (%)

Detected (ng/μL)

Accuracy (%)

CV (%)

(+)-tramadol

5.0

5.2 ± 0.1

103.4

1.91

5.2 ± 0.1

104.3

1.90

 

10.0

9.5 ± 0.3

96.0

3.29

9.6 ± 0.3

94.9

3.16

 

25.0

26.7 ± 0.4

103.9

1.56

26.0 ± 0.6

104.0

2.89

 

50.0

50.4 ± 0.9

100.0

1.70

50.0 ± 0.8

100.8

1.41

 

100.0

99.5 ± 2.2

100.3

2.20

100.3 ± 2.8

99.5

2.80

(-)-tramadol

5.0

4.9 ± 0.2

94.8

4.10

4.7 ± 0.2

98.0

4.30

 

10.0

9.5 ± 0.3

96.5

2.79

9.4 ± 0.2

94.5

2.25

 

25.0

26.1 ± 0.9

104.5

3.44

26.1 ± 0.3

104.4

1.18

 

50.0

50.7 ± 0.9

99.1

1.82

49.6 ± 0.4

101.4

0.88

 

100.0

100.6 ± 2.1

101.2

2.10

101.2 ± 2.8

100.6

2.44

  1. Data are expressed as the mean ± SD of 6 analyses.
  2. CV; coefficient of variation.