From: A sensitive method for analyzing fluconazole in extremely small volumes of neonatal serum
 | Method | Sample type | Sample volume (μL) | Sample preparation | LOQ (μg/mL) | Reference No. |
---|---|---|---|---|---|---|
1 | LC-MS | Serum | 25 | No pretreatment | 0.1 | [9] |
2 | LC-MS | Plasma | 50 | LLE | 0.0005 | [10] |
3 | LC-MS | Plasma | 50 | PP | 0.03 | [11] |
4 | LC-UV | Serum | 50 | SPE | 0.1 | [12] |
5 | LC-UV | Plasma | 50 | SPE | 0.2 | [13] |
6 | LC-MS | Plasma | 70 | PP | 0.01 | [14] |
7 | LC-MS | Serum | 75 | PP | 0.06 | [15] |
8 | LC-MS | Plasma | 100 | PP | 0.1 | [16] |
9 | LC-MS | Plasma | 100 | PP | 0.1 | [17] |
10 | LC-MS | Plasma | 100 | PP | 0.1 | [18] |
11 | LC-MS | Serum | 100 | PP | 0.2 | [19] |
12 | LC-MS | Plasma | 100 | DBS | 0.5 | [20] |
13 | LC-MS | Serum | 100 | PP | 0.5 | [21] |
14 | LC-UV | Plasma | 300 | SPE | 0.05 | [22] |
15 | LC-UV | Whole blood | 300 | SPE | 0.5 | [23] |
16 | LC-UV | Plasma | 500 | LLE | 0.4 | [24] |